Home > Products > Pocket-Sized Instruments >

LaiPen LP 100

LaiPen LP 100 measures Leaf Area Index (LAI), which is defined as the one-sided green leaf area per unit ground surface area (LAI = leaf area / ground area, m2 / m2) in broadleaf canopies. The LaiPen LP 100 calculates LAI and other canopy structure attributes from solar radiation measurements made with a wide-angle optical sensor. Measurements made above and below the canopy are used to determine canopy light interception at five angles, from which LAI is computed using a model of radiative transfer in vegetative canopies.

The LaiPen was designed by scientists and engineers to provide its user quick and reliable results. Unlike in other similar devices measuring LAI, the LaiPen LP 100 is accurate in most daylight conditions and does not require cloud cover or specific sun angles for its proper performance.

LaiPen LP 100 can work in two operation modes:
- Single sensor mode - reference measurement is taken before, after or during measurement with the same instrument
- Two sensor mode - second instrument is used for automatic logging of reference signal

LaiPen LP 100

  • Leaf Area Index (LAI):
  • Photosynthetically Active Radiation (PAR):
    Photosynthetically Active Radiation measured as Photosynthetic Photon Flux Density (PPFD)
  • LaiPen LP 100
  • High sensitivity
  • Integrated sensor for measuring foliage inclination
  • Measurement in five different acceptance angles - light is taken from five different zenith angles with one reading
  • Fast and easily repeatable measurements with instant readouts
  • Manual and automatic measurement
  • Lightweight, robust and battery-powered device with simple two-button operation
  • Large internal data storage
  • USB communication
  • External GPS module (optional)
  • LaiPen LP 100
  • Studies of canopy growth and productivity
  • Studies of forest dynamism
  • Research on air pollution or insect impact on foliage health
  • Great for rapid, repeated measurements and for large plant screening programs
  • Remote sensing
  • Global carbon cycle
  • LaiPen LP 100
  • Comprehensive software with data collection, analysis and visualization
  • USB communication
  • Visualization and data transfer routines to Microsoft Excel
  • Regular firmware updates
  • GPS mapping plug-in (optional)
  • Measured Parameters:
    - Leaf Area Index (LAI)
    - Photosynthetically Active Radiation (PAR)
  • Detector Wavelength Range:
    - 400 to 700 nm bandpass filters for PAR measurement
    - 400 to 500 nm bandpass filters for LAI measurement
  • View Restricting Cap:
    - Horizontal field of view: 112º
    - Vertical field of view: 16º
  • Foliage Inclination of Measurement:
    View angles: 0º, 16º, 32º, 48º, 64º
  • Memory Capacity:
    Up to 16 Mb
  • Display:
    2 x 8 characters LC display
  • Keypad:
    Sealed, 2-key tactile response
  • Keypad Escape Time:
    Turns off after 8 minutes of no use
  • Power Supply:
    4 AAA alkaline or rechargeable batteries
  • Battery Life:
    48 hours typical with full operation
  • Low Battery Detection:
    Low battery indication displayed
  • Size:
    120 mm x 57 mm x 30 mm 4.7" x 2.2" x 1.2"
  • Weight:
    180 g, 6.5 oz
  • Operating Conditions:
    Temperature: 0 to 55 ºC; 32 to 130 ºF Relative humidity: 0 to 95 % (non-condensing)
  • Storage Conditions:
    Temperature: -10 to +60 ºC; 14 to +140 ºF Relative humidity: 0 to 95 % (non-condensing)
  • Warranty:
    1 year parts and labor
  • POKORNÝ, R., TOMÁŠKOVÁ, I., HAVRÁNKOVÁ, K. (2008): Temporal variation and efficiency of LAI in young mountain Norway spruce stand. European Journal of Forest Research. Volume 127, Pages 359-367. DOI: 10.1007/s10342-008-0212-z
  • JONCKHEERE I., FLECK S., NACKAERTS K. ET AL. (2004): Review of methods for in situ leaf area index (LAI) determination. Part I. Theories, sensors and hemispherical photography. Agricultural and Forest Meteorology. Volume 121, Pages 19-35. DOI: 10.1016/j.agrformet.2003.08.027
  • NILSON, T. AND KUUSK, A. (2004): Improved algorithm for estimating canopy indices from gap fraction data in forest canopies. Agricultural and Forest Meteorology, Volume 124, Pages 157–169. DOI:10.1016/j.agrformet.2004.01.008
  • WEISS, M., BARET, F., SMITH, G. J., JONCKHEERE, I., COPPIN, P. (2004): Review of methods for in situ leaf area index (LAI) determination. Part II. Estimation of LAI, errors and sampling. determination. Agricultural and Forest Meteorology, 121 (1-2): 37–53. DOI:10.1016/j.agrformet.2003.08.001
  • POKORNÝ, R. AND MAREK, M. V. (2000):Test of accuracy of LAI estimation by LAI-2000 under artificially changed leaf to wood area proportions. Biologia Plantarum 43 (4): 537-544. DOI: 10.1023/A:1002862611176

Pricing

  • Orders and Payments
  • LaiPen LP 100/USB
    1.999,- €
  • Mini-Computer *
    390,- €
  • Standard Tripod *
    39,- €
  • Carrying Rod *
    39,- €
  • Substitute USB Communication Cable *
    39,- €
  • GPS Module *
    249,- €
  • Battery Charger *
    49,- €

Optional Features and Accessories

Mini-Computer
Small, portable notebook (type according to current availability on the market).


Standard Tripod
Tripod holder providing with the flexibility to pick the ideal location for automatic readings in open plot.


Carrying Rod
Rod for measuring above shrubs and undergrowth.


GPS Module
To record the exact location of the measurements performed by the pen-category instruments.


Battery Charger
Includes battery charger and 4 AAA alkaline rechargeable batteries. EU norm only.


Substitute USB Communication Cable
Substitute USB cable allowing connection between the "pen" devices and a PC (the device is delivered with one USB cable, which is included in the device price).

Download

Software
FluorPen 1.0
OS: Windows 2000 / Windows XP / Windows 7 (32bit, 64bit) / Windows 8 (32 bit, 64bit)/ Windows 10 (32 bit, 64bit),
Language: English
Size: 11.1 MB


SpectraPen_PolyPen 1.0.0.7
OS: Windows 7 (32bit, 64bit) and higher
Language: English
Size: 901 KB


USB Driver for Pen Devices
OS: Windows
Language: English
Size: 2.0 MB


Documents
FluorPen Series Manual
Type: PDF
Language: English
Size: 4.7 MB


FluorPen - List of References
Type: PDF
Language: English
Size: 779 KB


FluorPen Explain
Type: PDF
Language: English
Size: 2.8 MB


SpectraPen SP 100 Manual
Type: PDF
Language: English
Size: 1.4 MB


SpectraPen SP 100 - List of References
Type: PDF
Language: English
Size: 131 KB


SpectraPen LM 500 Manual
Type: PDF
Language: English
Size: 2.9 MB


PolyPen Manual
Type: PDF
Language: English
Size: 2.2 MB


PolyPen - List of References
Type: PDF
Language: English
Size:


AquaPen Manual
Type: PDF
Language: English
Size: 4.1 MB


AquaPen Manual (Czech)
Type: PDF
Language: English
Size: 4.0 MB


AquaPen - List of References
Type: PDF
Language: Czech
Size: 1.1 MB


LaiPen Manual
Type: PDF
Language: English
Size: 2.0 MB


LaiPen - List of References
Type: PDF
Language: English
Size: 135 KB


N-Pen Brief Guide
Type: PDF
Language: English
Size: 104 KB


N-Pen - List of References
Type: PDF
Language: English
Size:


PlantPen NDVI-PRI Operation Manual
Type: PDF
Language: English
Size: 2.7 MB


PlantPen - List of References
Type: PDF
Language: English
Size: 181 KB


Other Pocket-Sized-Instruments

FluorPen FP 100

FluorPen is a hand-held fluorometer that measures chlorophyll fluorescence parameters in a fully automated and rapid manner.
Applications:
- Photosynthesis Research & Education
- Large plant screening programs
- Agriculture & Forestry
- Biotechnology


PAR-FluorPen FP 100-MAX-LM

PAR-FluorPen is used to measure fluorescence and Photosynthetic Photon Flux Density (PPFD) of photosynthetically active radiation (PAR).
Applications:
- Photosynthesis Research & Education
- Plant & Molecular Biology
- Agriculture & Forestry
- Biotechnology


Monitoring Pen MP 100

Monitoring Pen is a robust and weather-proof version of the popular FluorPen that is intended for unattended use in a field.
Applications:
- Photosynthesis Research & Education
- Long-Term, Autonomous Fluorometry Experiments


AquaPen-C AP-C 100

AquaPen-C is a new cuvette version of the popular FluorPen fluorometer. It is optimized for measuring chlorophyll fluorescence in green algae and cyanobacteria. AquaPen sensitivity 500 ng Chl/l enables measuring in natural water.
Applications:
- Photosynthesis Research & Education
- Biotechnology
- Limnology & Oceanography


AquaPen-P AP-P 100

AquaPen-P is equipped with a submersible optical probe. It suits investigations in algal suspensions and natural waters. AquaPen sensitivity: 500 ng Chl/l.
Applications:
- Photosynthesis Research & Education
- Phycology
- Limnology & Oceanography
- Biotechnology


SpectraPen LM 500

SpectraPen with precise radiometric calibration and integrated cosine corrector. Number of formulas and calculated parameters: PAR, Watt, Lux, Lumen, CIE color coordinates, color rendering indexes, color temperatures.
Applications:
- Light Characteristics Measurements
- Light Source Testing and Quality Control
- Color Measurement


SpectraPen SP 100

SpectraPen is a handheld, programmable spectrophotometer that provides instant readings and spectral lines on interactive touch screen.
Applications:
- Visible Light Source Testing
- Color Measurement
- Chemical Measurement


PolyPen RP 400

PolyPen RP 400 is a complete system for measurement of spectral reflectance on flat leaves as well as measurements of transmittance and absorbance of any external light source. Integrated software is capable of automatic calculation of all common vegetation indices.


PlantPen PRI 200 & NDVI 300

PlantPen is a low-cost, handheld device that characterizes plants by means of reflectance. The two standard versions measure PRI and NDVI.
Applications:
- Photosynthesis Research & Education
- Vegetation Productivity
- Vegetation Stress Studies
- Agriculture


N-Pen N 100

N-Pen is a light-weight, battery-powered instrument that provides quick measurement of actual nitrogen content in plants throughout their growing season.
Applications:
- Significant Yield Increase
- Quick Tuning of Nitrogen Management in Crops
- Saving Nitrogen Application Costs


LaiPen LP 100

LaiPen is a light-weight, battery-powered device that mesures Leaf Area Index (LAI) and Photosynthetically Active Radiation (PAR). It provides fast and easily repeatable measurements with instant readouts that can be exported to a PC for further processing.
Applications:
- Studies of Canopy Productivity
- Studies of Forest Dynamism
- Remote Sensing


Video Gallery