AquaPen-P is a handheld fluorometer that enables rapid and accurate measurement of photosynthetic parameters in suspensions. It is equipped with a single blue LED emitter (optionally red or white), optically filtered and precisely focused to deliver light intensities of up to 3,000 µmol(photon).m-2.s-1 to measured algal cultures.
The measurements are carried out by a submersible optical probe. The AquaPen-P excels in a very high sensitivity - up to 0.5 µg Chl/l. Thus, it can measure even natural water samples containing low concentrations of phytoplankton. It can be favorably used both for the lab and field applications.
Data transfer is via USB or Bluetooth communication. Comprehensive FluorPen 1.0 software provides data transfer routines and many additional features for data presentation in tables and graphs. Parameters recorded by the AquaPen-P include FT, QY, NPQ, OJIP Analysis, and Light Curve.
- Photosynthesis research
- Photosynthesis education
- Phycology
- Limnology
- Oceanography
- Biotechnology
-

- FT - Instantaneous Chlorophyll Fluorescence. FT is equivalent to F0 if the sample is dark-adapted.
- QY - Quantum Yield. QY is a measure of the Photosystem II efficiency. QY is equivalent to FV/FM in dark-adapted samples and to FV ' /FM ' in light-adapted samples.
- OJIP - Chlorophyll Fluorescence Transient. OJIP measurement is used as an important biophysical signal that reflects the time course of photosynthesis.
- NPQ - Non-Photochemical Quenching. NPQ indicates thermal dissipation of absorbed light energy during photosynthesis.
- LC - Light Curve. Photosystem II Quantum Yield estimated from fluorescence that is measured sequentially in several different light levels.

- Two predefined NPQ protocols differing in the duration of light exposure and dark recovery phase as well as in the number of intervals between the pulses
- Typically used for quantification of photochemical and non-photochemical quenching in dark-adapted samples
- NPQ 1 protocol: light duration 60s, 5 pulses; dark recovery duration 88s, 3 pulses
- NPQ 2 protocol: light duration 200s, 10 pulses; dark recovery duration 390s, 7 pulses

- Three predefined protocols differing in number and duration of single light phases and light intensities
- Based on pulse modulated fluorometry
- Successive measurments of the sample photosynthesis under various light intensities of continuous illumination
- Light response curve relating the rate of photosynthesis to photon flux density

- Bckg = background
- F0: = F50µs; fluorescence intensity at 50 µs
- FJ: = fluorescence intensity at j-step (at 2 ms)
- Fi: = fluorescence intensity at i-step (at 60 ms)
- FM: = maximal fluorescence intensity
- FV: = FM - F0 (maximal variable fluorescence)
- VJ = (FJ - F0) / (FM - F0)
- Vi = (Fi - F0) / (FM - F0)
- FM / F0
- FV / F0
- FV/ FM
- M0 or (dV / dt)0 = TR0 / RC - ET0 / RC = 4 (F300 - F0) / (FM - F0)
- Area = area between fluorescence curve and FM (background subtracted)
- Fix Area = total area above the OJIP fluorescence transient - between F40µ and F1s(background subtracted)
- SM = area / FM - F0 (multiple turn-over)
- Ss = the smallest Sm turn-over (single turn-over)
- N = SM . M0 . (1 / VJ) turn-over number QA
- Phi_P0 = 1 - (F0 / FM (or FV / FM)
- Psi_0 = 1 - VJ
- Phi_E0 = (1 - F0 / FM)) . Psi_0
- Phi_D0 = 1 - Phi_P0 - (F0 / FM)
- Phi_Pav = Phi_P0 - (SM / tFM); tFM) = Time to reach FM (in ms)
- ABS / RC = M0 . (1 / VJ) . (1 / Phi_P0)
- TR0 / RC = M0 . (1 / VJ)
- ET0 / RC = M0 . (1 / VJ) . Phi_0)
- DI0 / RC = (ABS / RC) - (TR0 / RC)
- Formulas Derived From:
R.J. Strasser, A. Srivastava and M. Tsimilli-Michael (2000): The fluorescence transient as a tool to characterize and screen photosynthetic samples. In: Probing Photosynthesis: Mechanism, Regulation and Adaptation (M. Yunus, U. Pathre and P. Mohanty, eds.), Taylor and Francis, UK, Chapter 25, pp 445-483. 
Transport Case
- FluorPen 1.0 software (Windows 2000, XP, or higher compatible*)
- Bluetooth, USB or serial communication
- Real-time and remote control functions
- Export to Microsoft Excel
- GPS mapping plug-in

FluorPen Software Window: OJIP Curves With Data Sheet
- Measured/Calculated Parameters:
F0 ; FT ; FM ; FM ' ; QY; OJIP; NPQ 1,2; LC 1,2,3 - Saturating Light:
Adjustable from 0 to 100 % (up to 3,000 µmol(photon).m-2.s-1 - Actinic Light:
Adjustable from 0 to 100 % (up to 1,000 µmol(photon).m-2.s-1 - Measuring Light:
Adjustable from 0 to 100 % (up to 3,000 µmol(photon).m-2.s-1 - Emitter:
Blue 455 nm LED (optionally red or white) - optically filtered and precisely focused - Detector Wavelength Range:
PIN photodiode with 667 to 750 nm bandpass filters - FluorPen 1.0 Software:
Windows 2000, XP, or higher* - Memory Capacity:
Up to 4 Mb - Internal Data Logging:
Up to 100,000 data points - Display:
2 x 8 characters LC display - Keypad:
Sealed, 2-key tactile response - Keypad Escape Time:
Turns off after 3 minutes of no use - Power Supply:
4 AAA alkaline or rechargeable batteries - Battery Life:
48 hours typical with full operation - Low Battery Detection:
Low battery indication displayed - Size:
140 x 55 x 50 mm; 5.5 " x 2.2" x 2.0" - Weight:
300 g, 10.6 oz - Sample Holder:
Submersible optical probe - 80 mm long; lightguide diameter 8 mm; lightguide end 15 mm in diameter - Operating Conditions:
Temperature: 0 to 55 ºC; 32 to 130 ºF. Relative humidity: 0 to 95 % (non-condensing) - Storage Conditions:
Temperature: -10 to +60 ºC; 14 to +140 ºF. Relative humidity: 0 to 95 % (non-condensing) - Warranty:
1 year parts and labor
Pricing
- Orders and Payments
- AquaPen-P AP-P 100 1.999,- €
- Mini-Computer * 390,- €
- GPS Module * 249,- €
- Battery Charger * 49,- €
- Transport Case * 79,- €
Optional Features and Accessories
Mini-Computer
Small, portable notebook: light-weight (1 kg), long battery runtime (about 4 hours), 10.1-inch display, 1 GB memory, integrated Bluetooth, WLAN and LAN, Windows 7 installed.
GPS Module
To record the exact location of the measurements performed by the pen-category instruments.
Battery Charger
To recharge batteries used in the pen-category instruments. Includes a battery charger and 4 AAA batteries. EU norm only.
Transport Case
Padded case to shelter all necessary accessories. Size: 25 x 22 x 5 cm.
Download
FluorPen 1.0
OS: Win2000/XP
Language: English
Size: 2.2MB
Documents
FluorPen Series Manual
Type: PDF
Language: English
Size: 1.2MB
FluorPen Quick Guide
Type: PDF
Language: English
Size: 82kB
FluorPen Explain
Type: PDF
Language: English
Size: 2.9MB
SpectraPen Manual
Type: PDF
Language: English
Size: 247kB
AquaPen Manual
Type: PDF
Language: English
Size: 1.3MB
AquaPen Quick Guide
Type: PDF
Language: English
Size: 85kB
N-Pen Brief Guide
Type: PDF
Language: English
Size: 106kB
GFP-Pen Manual
Type: PDF
Language: English
Size: 812kB
PlantPen NDVI Manual
Type: PDF
Language: English
Size: 363kB
PlantPen PRI Manual
Type: PDF
Language: English
Size: 390kB
PlantPen NDVI, PRI Quick Guide
Type: PDF
Language: English
Size: 73,7kB
Other Pocket-Sized-Instruments
FluorPen is a hand-held fluorometer that measures chlorophyll fluorescence parameters in a fully automated and rapid manner.
Applications:
- Photosynthesis Research & Education
- Large plant screening programs
- Agriculture & Forestry
- Biotechnology
PAR-FluorPen FP 100-MAX-LM
PAR-FluorPen is used to measure fluorescence and Photosynthetic Photon Flux Density (PPFD) of photosynthetically active radiation (PAR).
Applications:
- Photosynthesis Research & Education
- Plant & Molecular Biology
- Agriculture & Forestry
- Biotechnology
AquaPen-C AP-C 100
AquaPen-C is a new cuvette version of the popular FluorPen fluorometer. It is optimized for measuring chlorophyll fluorescence in green algae and cyanobacteria. AquaPen sensitivity 500 ng Chl/l enables measuring in natural water.
Applications:
- Photosynthesis Research & Education
- Biotechnology
- Limnology & Oceanography
AquaPen-P AP-P 100
AquaPen-P is equipped with a submersible optical probe. It suits investigations in algal suspensions and natural waters. AquaPen sensitivity: 500 ng Chl/l.
Applications:
- Photosynthesis Research & Education
- Phycology
- Limnology & Oceanography
- Biotechnology
SpectraPen SP 100
SpectraPen is a handheld, programmable spectrophotometer that provides instant readings and spectral lines on interactive touch screen.
Applications:
- Visible light source testing
- Color measurement
- Chemical measurement
Poly-PlantPen RP 400
Poly-PlantPen RP 400 is a complete system for measurement of spectral reflectance on flat leaves. It runs on Li-Ion rechargeable battery and does not require any external PC. Integrated software is capable of automatic calculation of all common vegetation indices.
PlantPen PRI 200 & NDVI 300
PlantPen is a low-cost, handheld device that characterizes plants by means of reflectance. The two standard versions measure PRI and NDVI.
Applications:
- Photosynthesis Research & Education
- Vegetation Productivity
- Vegetation Stress Studies
- Agriculture
N-Pen N 100
N-Pen is a light-weight, battery-powered instrument that provides quick measurement of actual nitrogen content in plants throughout their growing season.
Applications:
- Significant Yield Increase
- Quick Tuning of Nitrogen Management in Crops
- Saving Nitrogen Application Costs
GFP-Pen GFP 100
GFP-Pen is a handheld fluorometer that serves rapid measurements of the Green Fluorescent Protein (GFP).
Applications:
- GFP measurement in intact leaf samples
- Distinguish between GMO and non-GMO
- Gene expression studies
- Transgenic crop research