Gas Mixing System GMS 150 can produce precise mixtures of up to 4 different gasses. The flows of the individual input gases are measured by thermal mass flow meters and adjusted by integrated mass flow controllers. Before the exit connector, the gas mixture is thoroughly homogenized. The input and output gas connectors are of Prestolok type allowing fast and secure connection to a variety of tubes.
The GMS 150 mass flow meters and controllers can operate gas flows ranging from mln/min to tens of ln/min. Typically, the controllers of GMS 150 operate in the lowest range 0-8 mln/min and in the highest range 0-2500 mln/min. GMS 150 is typically used to control flow of air, carbon dioxide, and nitrogen. Additional gases like nitrogen dioxide, carbon monoxide, methane, ammonia and others can also be added to simulate various technological mixtures or smokestack gasses.

One of the GMS 150 Control Screens
The GMS 150 can be used as a stand-alone instrument or as a constituent part of the PSI Photobioreactor FMT 150 and FytoScopes. It can be controlled locally from its front panel. The user can define the required gas mixture either by setting the flows of the individual gasses (e.g., 980 mln/min of N2 and 20 mln/min of CO2) or by setting the required relative composition of the gas mixture (2% CO2) and the mixture gas flow (1000 mln/min).
Pricing
- Orders and Payments
- 2-Channel Gas Mixing System GMS 150 8.680,- €
- Additional Channel to Gas Mixing System GMS 150 3.500,- €
Download
Nothing
Documents
Magnetic Stirrer Manual
Type: PDF
Language: English
Size: 110kB
OxyCorder Manual
Type: PDF
Language: English
Size: 928kB
Thermoregulator Manual
Type: PDF
Language: English
Size: 178Kb
Gas Mixing System Manual
Type: PDF
Language: English
Size: 2.5Mb
Other Instruments
Thermoregulator TR 2000 provides precise temperature control of liquid samples in the range of 0°C to +70°C with an accuracy of 0.1°C. It can work in two modes - constant and temperature ramp mode. The Thermoregulator can be favorably used with the PSI Fluorometers.
Gas Mixing System GMS 150
High-precision GMS 150 can produce mixtures of up to 4 different gases. The flows of the individual input gases are measured by thermal mass flow meters and adjusted by integrated mass flow controllers. It can be used as a stand-alone instrument or in a system with the PSI Photobioreactors.
Peristaltic Pump PP 500 / PP 550
Peristaltic Pump is used for accurate and reproducible fluid transfer in laboratories and industry. The pump allows diverse operation modes (chemostat, pHstat, turbidostat) and variable flow-rate range from 10 to 5600 µl/min.
Magnetic Stirrer
Magnetic Stirrer is designed to provide continuous stirring with little speed deviation and minimal heat build-up. It is a handy accessory to the PSI Fluorometers.
OxyCorder 401
The primary application of the instrument is the polarographic measurement of dissolved oxygen by a Clark electrode.